• We can help. Call 800-354-8556

Badger BGR-DQ-G-KZ-B-S-AK-WW-S-XX-SGF Ultrasonic Flow Sensor

Ultrasonic, Flow, 2.5-12" EZ Rail,120-220VAC, 50' cables, Cable Gland,BN/MB

  • Brand Name: Veris
  • Veris Part#: BGR-DQ-G-KZ-B-S-AK-WW-S-XX-SGF
  • Est. Shipping Date: loading
Application      :      Flow
Communication Protocol      :      EIA-485: Modbus RTU or BACnet MS/TP
Display Type      :      128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout; polycarbonate window Flow rate/total: 8-digit
Field Programmable      :      Yes
Fitting Size      :      2.5-12" Medium Pipe
Flow Measurement Accuracy      :      ± 0.5% ± 0.025 ft/s (0.008 m/s) of reading
Flow Measurement Range      :      1 - 20 ft/s (0.3 - 6 m/s)
Flow Measurement Repeatability      :      0.2% above 1.5 ft/s
Flow Sensor Type      :      Ultrasonic
Housing      :      Aluminum construction, EPDM Gasket, NEMA Type 4X, IP67, 0.5" NPT Threads, with Poly Cable Glands
Input Power      :      85 to 264V AC 47 to 63 Hz @ 24VA max. 1 Amp slow-blow fuse, manually field replaceable. Over-Voltage Rating Category II (CAT II)
Keypad      :      4-button navigation, keypad with tactile feedback; polyester film
Measurement Type      :      Flow
Medium      :      Water, sewage, cooling water, glycol, alcohol and chemicals
Operating Fluid Temperature      :      14 - 150 °F (-10 - 65 °C)
Operating Temperature      :      -4 to 140 ° F (-20 to 60 °C)
Outputs      :      4 to 20mA x 2 ; Frequency Output, Pulse (totalizer, programmable)
Pipe Material      :      Copper | Polymer | Steel | Stainless Steel
Product Type      :      Sensor
Transducer Construction      :      PBT glass filled, Ultem®, Nylon cord grip; PVC cable jacket; –40 to 250° F (–40 to 121° C)
Transducers      :      2 Included. For 2.5-12" Medium Pipe EZ Rail with 50' Cables
Warranty      :      1 year

Transit time flow meters measure the time difference between the travel time of an ultrasound wave going with the fluid flow and against the fluid flow. The time difference is used to calculate the velocity of the fluid traveling in a closed-pipe system. The transducers used in transit time measurements operate alternately as transmitters and receivers. Transit time measurements are bi-directional and are most effective for fluids that have low concentrations of suspended solids and are sonically conductive.

An ultrasonic meter equipped with heat flow capabilities measures the rate and quantity of heat delivered or removed from devices such as heat exchangers. By measuring the volumetric flow rate of the heat exchanger liquid, the temperature at the inlet pipe and the temperature at the outlet pipe, the energy usage can be calculated.

  • pdf Datasheet https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/TFX5000_d1023.pdf