• We can help. Call 800-354-8556

Badger BGR-DR-G-CB-R-S-AKWWCAKNXXTGRF Ultrasonic Flow Sensor

Ultrasonic, Flow, BTU, 3/4" Steel,110-220VAC, 50' cables, BACnet/Modbus

  • Brand Name: Veris
  • Veris Part#: BGR-DR-G-CB-R-S-AKWWCAKNXXTGRF
  • Est. Shipping Date: loading
Application      :      Flow and Energy Monitoring
Communication Protocol      :      EIA-485: Modbus RTU or BACnet MS/TP Ethernet: 10/100 Base T RJ45, communication via Modbus TCP/IP
Display Type      :      128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout; polycarbonate window Flow rate/total: 8-digit
Field Programmable      :      Yes
Flow Measurement Accuracy      :      ± 0.5% ± 0.025 ft/s (0.008 m/s) of reading
Flow Measurement Range      :      1 - 20 ft/s (0.3 - 6 m/s)
Flow Measurement Repeatability      :      0.2% above 1.5 ft/s
Flow Sensor Type      :      Ultrasonic
Housing      :      Aluminum construction, EPDM Gasket, NEMA Type 4X, IP67
Input Power      :      85 to 264V AC 47 to 63 Hz @ 24VA max. 1 Amp slow-blow fuse, manually field replaceable. Over-Voltage Rating Category II (CAT II)
Keypad      :      4-button navigation, keypad with tactile feedback; polyester film
Measurement Type      :      Flow and BTU
Medium      :      Water delivery, sewage, cooling water, glycol, alcohol and chemicals
Operating Fluid Temperature      :      14 - 150 °F (-10 - 65 °C)
Operating Temperature      :      -4 to 140 ° F (-20 to 60 °C)
Outputs      :      4 to 20mA x 2 ; Frequency Output, Pulse (totalizer, programmable)
Pipe Material      :      Steel
Product Type      :      Sensor
Temperature Sensor      :      2 Included. Strap-on for BTU with 50' Cables
Transducer Construction      :      CPVC, Ultem ®, Nylon cord grip, PVC cable jacket; –40 to 194° F (-40 to 90°C)
Transducers      :      2 Included. For 3/4" Steel Pipe with 50' Cables
Warranty      :      1 year

Transit time flow meters measure the time difference between the travel time of an ultrasound wave going with the fluid flow and against the fluid flow. The time difference is used to calculate the velocity of the fluid traveling in a closed-pipe system. The transducers used in transit time measurements operate alternately as transmitters and receivers. Transit time measurements are bi-directional and are most effective for fluids that have low concentrations of suspended solids and are sonically conductive.

An ultrasonic meter equipped with heat flow capabilities measures the rate and quantity of heat delivered or removed from devices such as heat exchangers. By measuring the volumetric flow rate of the heat exchanger liquid, the temperature at the inlet pipe and the temperature at the outlet pipe, the energy usage can be calculated.

  • pdf Datasheet https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/TFX5000_d1023.pdf