• We can help. Call 800-354-8556

Veris H932 Current Transducer

Hawkeye 0 to 30/60/120 A Input 0 to 5 VDC Output Analog Current Transducer with 24 VAC/VDC SPST Relay, Split-Core, 1.1 x 0.8 in

  • Brand Name: Veris
  • Veris Part#: H932
  • Est. Shipping Date: loading
Application      :      Building Automation Systems
Current Measurement Accuracy      :      ±2% of F.S. above 10% of F.S.
Current Measurement Range      :      0 - 30 A | 0 - 60 A | 0 - 120 A
Current Sensor type      :      Current Transducer, AC
Electrical Wiring Size      :      24 - 14 AWG (0.2 - 2.1 mm²)
Measurement Type      :      AC Current
Model      :      H932
Monitored Frequency Range      :      50 - 60 Hz
Monitored Wire Size      :      0.8" (21 mm)
Mounting      :      Split Core
Operating Humidity      :      10 - 90% RH, non-condensing
Operating Temperature      :      5 - 140 °F (-15 - 60 °C)
Output Specifications      :      0 - 5 VDC
Outputs      :      Analog output | Relay
Product Certification      :      UL | CE
Product Type      :      Sensor
Range      :      HX32 Series
Relay Coil Voltage      :      24 VAC/DC
Relay Construction      :      Mechanical
Relay Contact Ratings      :      Resistive: 5 A @ 250 VAC | Resistive: 5 A @ 30 VDC | Inductive: 2 A @ 250 VAC | Inductive: 2 A @ 30 VDC
Relay Poles/Throw      :      SPST
Warranty      :      5 years

The Hawkeye H932 series provide accurate load trending information with a proportional 0 to 5 VDC output signal. This feature combined with an integrated command relay makes these products ideal for start/stop and status monitoring of motors. The relay is fully isolated from the current sensor and all relay connections are externally available for maximum flexibility.

  • Self-powered analog current transducer with integral start/stop command relay
  • Reduces the number of installed components, saves time and space
  • Self-gripping, split-core design for fast retrofit installation, no need to remove conductor
  • Reduces installation charges - one device to install for start/stop and status
  • No external power required for current sensor
  • Selectable factory calibrated ranges up to 120 A for increased flexibility and resolution
  • Induced from monitored conductor sensor power