• We can help. Call 800-354-8556

Veris CDLSXTD Duct CO2 Sensor

Deluxe High-Impact ABS Plastic 10 kOhm T2 Thermistor CO2 and Temperature Sensor with LCD Display

  • Brand Name: Veris
  • Veris Part#: CDLSXTD
  • Est. Shipping Date: loading
Application Zone      :      Plant Room
Application      :      Duct
Brand      :      Veris
CO2 Measurement Accuracy      :      ±30 ppm ±2% of measured value
CO2 Measurement Range      :      0 - 2000 ppm | 0 - 5000 ppm
CO2 Measurement Repeatability      :      ±20 ppm ±1% of measured value
CO2 Measurement Resolution      :      1 ppm
CO2 Sensor Type      :      NDIR
Color      :      Cloud White
Dimension Depth      :      2.4" (61 mm)
Dimension Height      :      3.1" (78 mm)
Dimension Probe Diameter      :      1" (25.4 mm)
Dimension Probe Length      :      7.8" (198 mm)
Dimension Width      :      6.7" (170 mm)
Display Resolution      :      2 Rows x 8 Characters
Display Size      :      1.2" x 0.6" (30,5 mm x 14 mm)
Display Type      :      LCD
Electrical Wiring Size      :      24 - 14 AWG (0.22 - 2.5 mm²)
Enclosure Material      :      ABS Plastic
Measurement Type      :      CO2 | Temperature
Mounting      :      Duct
Operating Humidity      :      0 - 95% RH, non-condensing
Operating Temperature      :      32 - 122 °F (0 - 50 °C)
Output Specifications      :      4 - 20 mA | 0 - 5 V | 0 - 10 V
Outputs      :      Analog output | Resistive temperature output
Product Certification      :      CE
Product Type      :      Sensor
Range      :      CDL
Response Time      :      CO2: <60 seconds for 90% step change
Supply Voltage AC Nominal      :      24 VAC
Supply Voltage DC Nominal      :      20 - 30 VDC
Temperature Calibration Certificate      :      None
Temperature Measurement Accuracy      :      ±1.8 °F (±1.0 °C)
Temperature Measurement Range      :      -58 - 302 °F (-50 - 150 °C)
Temperature Sensor Type      :      10k Ohm Type 2 Thermistor
Warranty      :      5 years

CDL carbon dioxide (CO2) sensors maximize energy savings, while helping optimize ventilation. These sensors allow ventilation systems to be controlled by the amount of CO2 present in a space. The CDL series detect fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for the space at a given time saving energy and increasing tenant comfort.

  • Microprocessor based design increases accuracy and reduces installation time
  • Self-calibrating - innovative self-calibration algorithm easy to maintain
  • Non-dispersive infrared technology (NDIR) repeatable to +/-20 ppm +/-1% of measured value high accuracy measurement
  • Snap-on faceplate no screws required, making installation and service easy
  • Field-selectable outputs for operation flexibility
  • Integrated probe - integrated transducer and probe eliminates the need to install a separate pick-up tube
  • Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) US Patent 5,844,138 HS sensor
  • Solid-state, integrated circuit sensor
  • pdf CE Declaration https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/CDLS_CEDec12091.pdf
  • pdf Datasheet https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/CD Series_d0321.pdf