• We can help. Call 800-354-8556

Veris H614 Current Switch

Hawkeye 1.5 to 150 A Auto Calibration VFD Current Switch, Split-Core

  • Brand Name: Veris
  • Veris Part#: H614
  • Est. Shipping Date: loading
Application      :      Building Automation Systems
Current Measurement Range      :      1.5 - 150 A
Current Sensor type      :      Current Switch, VFD, Automatic
Electrical Wiring Size      :      24 - 14 AWG (0.2 - 2.1 mm²)
Measurement Type      :      AC Current | VFD
Model      :      H614
Monitored Frequency Range      :      12 - 115 Hz
Monitored Wire Size      :      0.5" (12 mm)
Mounting      :      Split Core
Operating Humidity      :      10 - 90% RH, non-condensing
Operating Temperature      :      5 - 140 °F (-15 - 60 °C)
Output Specifications      :      N.O. 1 A @ 30 VAC/DC
Outputs      :      Switch output
Product Certification      :      UL | CE
Product Type      :      Sensor
Range      :      VFD Series
Relay Coil Voltage      :      None
Relay Contact Ratings      :      None
Relay Poles/Throw      :      None
Reset      :      Manual
Setpoint      :      Automatic Calibration
Warranty      :      5 years

The Hawkeye H614 is a microprocessor based, self-learning, self calibrating current-sensitive switching device designed for use with VFD systems. At initial power-up, the H614 automatically learns the average current on the line with no action required by the installer. Once a current is learned, the switch monitors for changes in current greater than +/-20% of the learned load. When calibrated for a given VFD system, the H614 is tolerant of gradual drifts in frequency due to expected conditions, such as an accumulation of debris in a filter, while still detecting a sudden drop due to a potential abnormal system condition (e.g., belt loss or other mechanical failure).

  • Microcontroller based learning technology - automatically learns load upon initial power-up minimizes calibration labor
  • Automatic trip point - automatic trip point (1.5 to 150 A, 12 to 115 Hz) detect abnormal events
  • Under and over-load - microcontroller based learning technology automatically learns load
  • Saves space - small size fits easily inside small starter enclosures
  • 100% solid-state no moving parts to fail
  • LED status
  • Induced from monitored conductor sensor power
  • pdf CE Declaration https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/h614-CEDec01131.pdf
  • pdf Datasheet https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/H614_d0321.pdf
  • pdf Installation Guide https://www.veris.com//ASSETS/DOCUMENTS/ITEMS/EN/H614_i0d2.pdf